Prisma · sdk · fg-0296

Queries hang or fail with 'Unable to start a transaction in the given time' after moving Prisma to driver adapters

Transaction API error: Unable to start a transaction in the given time.

Verified 2026-10-15 · Confirmed by 0 builders · Trust 50/100

Cause

With driver adapters the pool belongs to the driver. For pg that means 10 connections, no acquire or connect timeout, and a 10 second idle timeout, where Prisma 6 used CPUs times 2 plus 1 connections with a 10 second acquire and 5 second connect timeout.

Fix

Set pool size and timeouts on the adapter explicitly.

Apply

const adapter = new PrismaPg({
  connectionString: process.env.DATABASE_URL,
  max: 10,
  connectionTimeoutMillis: 5_000,
  idleTimeoutMillis: 300_000,
})

Affects: Prisma ORM 7.0 and later, and 6.x with the driverAdapters feature

Sources